کلید دژنگتور زیمنس ، کلیدی می باشد که وظیفه قطع و وصل کردن خط برق و حفاظت از شبکه برق های صنعتی را بر عهده دارد. کلید دژنگتور هنگام معیوب شدن قطعه آن را جدا می کند.
آیتم | کد | مشخصات |
1 | 3AE5082-1AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 7.2KV 16KA 800A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
2 | 3AE5082-2AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 7.2KV 16KA 1250A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
3 | 3AE5083-1AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 7.2KV 20KA 800A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
4 | 3AE5083-2AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 7.2KV 20KA 1250A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
5 | 3AE5084-1AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 7.2KV 25KA 800A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
6 | 3AE5084-2AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 7.2KV 25KA 1250A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
7 | 3AE5084-4AE40-0EN2 | Vacuum Circuit-Breaker SION 3AE5 7.2kV 25kA 2000A pole-center distance 210mm width across flats 310mm secondary equipment: operating cycle counter 2 position switches for signal closing spring charged closing solenoid 1st shunt release voltage of closing solenoid DC 110V voltage of 1st release DC 110V without 2nd release for fixed mounting voltage of drive motor DC 110V mechanical interlocking auxiliary switch 12NO+12NC breaker tripping signal secondary connection 64pole plug connector rating plate and operating instructions in english system frequency 50Hz |
8 | 3AE5085-1AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 7.2KV 31.5KA 800A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
9 | 3AE5085-2AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 7.2KV 31.5KA 1250A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
10 | 3AE5085-4AE40-0EN2 | Vacuum Circuit-Breaker SION 3AE5 7.2kV 31.5kA 2000A pole-center distance 210mm width across flats 310mm secondary equipment: operating cycle counter 2 position switches for signal closing spring charged closing solenoid 1st shunt release voltage of closing solenoid DC 110V voltage of 1st release DC 110V without 2nd release for fixed mounting voltage of drive motor DC 110V mechanical interlocking auxiliary switch 12NO+12NC breaker tripping signal secondary connection 64pole plug connector rating plate and operating instructions in english system frequency 50Hz |
11 | 3AE5085-6AE40-0EN2 | Vacuum Circuit-Breaker SION 3AE5 7.2kV 31.5kA 2500A pole-center distance 210mm width across flats 310mm secondary equipment: operating cycle counter 2 position switches for signal closing spring charged closing solenoid 1st shunt release voltage of closing solenoid DC 110V voltage of 1st release DC 110V without 2nd release for fixed mounting voltage of drive motor DC 110V mechanical interlocking auxiliary switch 12NO+12NC breaker tripping signal secondary connection 64pole plug connector rating plate and operating instructions in english system frequency 50Hz |
12 | 3AE1086-7AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE1 7.2KV 40KA 3150A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
13 | 3AE5182-1AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 12KV 16KA 800A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
14 | 3AE5182-2AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 12KV 16KA 1250A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
15 | 3AE5183-1AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 12KV 20KA 800A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
16 | 3AE5183-2AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 12KV 20KA 1250A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
17 | 3AE5184-1AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 12KV 25KA 800A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
18 | 3AE5184-2AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 12KV 25KA 1250A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
19 | 3AE5184-4AE40-0EN2 | Vacuum Circuit-Breaker SION 3AE5 12kV 25kA 2000A pole-center distance 210mm width across flats 310mm secondary equipment: operating cycle counter 2 position switches for signal closing spring charged closing solenoid 1st shunt release voltage of closing solenoid DC 110V voltage of 1st release DC 110V without 2nd release for fixed mounting voltage of drive motor DC 110V mechanical interlocking auxiliary switch 12NO+12NC breaker tripping signal secondary connection 64pole plug connector rating plate and operating instructions in english system frequency 50Hz |
20 | 3AE5184-6AE40-0EN2 | Vacuum Circuit-Breaker SION 3AE5 12kV 25kA 2500A pole-center distance 210mm width across flats 310mm secondary equipment: operating cycle counter 2 position switches for signal closing spring charged closing solenoid 1st shunt release voltage of closing solenoid DC 110V voltage of 1st release DC 110V without 2nd release for fixed mounting voltage of drive motor DC 110V mechanical interlocking auxiliary switch 12NO+12NC breaker tripping signal secondary connection 64pole plug connector rating plate and operating instructions in english system frequency 50Hz |
21 | 3AE5185-1AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 12KV 31.5KA 800A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
22 | 3AE5185-2AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 12KV 31.5KA 1250A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
23 | 3AE5185-4AE40-0EN2 | Vacuum Circuit-Breaker SION 3AE5 12kV 31.5kA 2000A pole-center distance 210mm width across flats 310mm secondary equipment: operating cycle counter 2 position switches for signal closing spring charged closing solenoid 1st shunt release voltage of closing solenoid DC 110V voltage of 1st release DC 110V without 2nd release for fixed mounting voltage of drive motor DC 110V mechanical interlocking auxiliary switch 12NO+12NC breaker tripping signal secondary connection 64pole plug connector rating plate and operating instructions in english system frequency 50Hz |
24 | 3AE5185-6AE40-0EN2 | Vacuum Circuit-Breaker SION 3AE5 12kV 31.5kA 2500A pole-center distance 210mm width across flats 310mm secondary equipment: operating cycle counter 2 position switches for signal closing spring charged closing solenoid 1st shunt release voltage of closing solenoid DC 110V voltage of 1st release DC 110V without 2nd release for fixed mounting voltage of drive motor DC 110V mechanical interlocking auxiliary switch 12NO+12NC breaker tripping signal secondary connection 64pole plug connector rating plate and operating instructions in english system frequency 50Hz |
25 | 3AE1186-2AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE1 12KV 40KA 1250A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
26 | 3AE1186-4AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE1 12KV 40KA 2000A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
27 | 3AE1186-6AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE1 12KV 40KA 2500A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
28 | 3AE1186-7AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE1 12KV 40KA 3150A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
29 | 3AE5284-1AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 17.5KV 25KA 800A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
30 | 3AE5284-2AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE5 17.5KV 25KA 1250A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
31 | 3AE5284-4AE40-0EN2 | Vacuum Circuit-Breaker SION 3AE5 17.5kV 25kA 2000A pole-center distance 210mm width across flats 310mm secondary equipment: operating cycle counter 2 position switches for signal closing spring charged closing solenoid 1st shunt release voltage of closing solenoid DC 110V voltage of 1st release DC 110V without 2nd release for fixed mounting voltage of drive motor DC 110V mechanical interlocking auxiliary switch 12NO+12NC breaker tripping signal secondary connection 64pole plug connector rating plate and operating instructions in english system frequency 50Hz |
32 | 3AE5284-6AE40-0EN2 | Vacuum Circuit-Breaker SION 3AE5 17.5kV 25kA 2500A pole-center distance 210mm width across flats 310mm secondary equipment: operating cycle counter 2 position switches for signal closing spring charged closing solenoid 1st shunt release voltage of closing solenoid DC 110V voltage of 1st release DC 110V without 2nd release for fixed mounting voltage of drive motor DC 110V mechanical interlocking auxiliary switch 12NO+12NC breaker tripping signal secondary connection 64pole plug connector rating plate and operating instructions in english system frequency 50Hz |
33 | 3AE1286-7AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE1 17.5KV 40KA 3150A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
34 | 3AE5324-1AE40-0EN2 | Vacuum Circuit-Breaker SION 3AE5 24kV 25kA 800A pole-center distance 210mm width across flats 310mm secondary equipment: operating cycle counter 2 position switches for signal closing spring charged closing solenoid 1st shunt release voltage of closing solenoid DC 110V voltage of 1st release DC 110V without 2nd release for fixed mounting voltage of drive motor DC 110V mechanical interlocking auxiliary switch 12NO+12NC breaker tripping signal secondary connection 64pole plug connector rating plate and operating instructions in english system frequency 50Hz |
35 | 3AE5324-2AE40-0EN2 | Vacuum Circuit-Breaker SION 3AE5 24kV 25kA 1250A pole-center distance 210mm width across flats 310mm secondary equipment: operating cycle counter 2 position switches for signal closing spring charged closing solenoid 1st shunt release voltage of closing solenoid DC 110V voltage of 1st release DC 110V without 2nd release for fixed mounting voltage of drive motor DC 110V mechanical interlocking auxiliary switch 12NO+12NC breaker tripping signal secondary connection 64pole plug connector rating plate and operating instructions in english system frequency 50Hz |
36 | 3AE1324-4AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE1 24KV 25KA 2000A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
37 | 3AE1324-6AE40-0EN2 | VACUUM CIRCUIT-BREAKER SION 3AE1 24KV 25KA 2500A POLE-CENTER DISTANCE 210MM WIDTH ACROSS FLATS 310MM SECONDARY EQUIPMENT : OPERATING CYCLE COUNTER 2 POSITION SWITCHES FOR SIGNAL CLOSING SPRING CHARGED CLOSING SOLENOID 1ST SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST RELEASE DC 110V, . FOR FIXED MOUNTING VOLTAGE OF MOTOR OP.MECHANISM DC 110V, MECHANICAL INTERLOCKING AUXILIARY SWITCH 12NO+12NC BREAKER TRIPPING SIGNAL SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE/OPERATING INSTRUCTIONS IN ENGLISH SYSTEM FREQUENCY 50HZ |
38 | 3AH4305-2TK88-8KC2 | VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 1250A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 2 SHUNT RELEASES UNDERVOLTAGE RELEASE VOLTAGE OF CLOSING SOLENOID AC 230V, VOLTAGE OF 1ST SHUNT RELEASE AC 230V, VOLTAGE OF 2ND SHUNT RELEASE AC 230V, VOLTAGE OF 3RD SHUNT RELEASE AC 230V, VOLTAGE OF OPERATING MECHANISM AC 230V, AUXILIARY SWITCH 12NO+12NC SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
39 | 3AH4305-2TE44-4EC2 | VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 1250A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 2 SHUNT RELEASES UNDERVOLTAGE RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, VOLTAGE OF 2ND SHUNT RELEASE DC 110V, VOLTAGE OF 3RD SHUNT RELEASE DC 110V, VOLTAGE OF OPERATING MECHANISM DC 110V, AUXILIARY SWITCH 12NO+12NC SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
40 | 3AH4305-4TK88-8KC2 | VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 2000A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 2 SHUNT RELEASES UNDERVOLTAGE RELEASE VOLTAGE OF CLOSING SOLENOID AC 230V, VOLTAGE OF 1ST SHUNT RELEASE AC 230V, VOLTAGE OF 2ND SHUNT RELEASE AC 230V, VOLTAGE OF 3RD SHUNT RELEASE AC 230V, VOLTAGE OF OPERATING MECHANISM AC 230V, AUXILIARY SWITCH 12NO+12NC SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
41 | 3AH4305-4TE44-4EC2 | VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 2000A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 2 SHUNT RELEASES UNDERVOLTAGE RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, VOLTAGE OF 2ND SHUNT RELEASE DC 110V, VOLTAGE OF 3RD SHUNT RELEASE DC 110V, VOLTAGE OF OPERATING MECHANISM DC 110V, AUXILIARY SWITCH 12NO+12NC SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
42 | 3AH4305-6TK88-8KC2 | VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 2500A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 2 SHUNT RELEASES UNDERVOLTAGE RELEASE VOLTAGE OF CLOSING SOLENOID AC 230V, VOLTAGE OF 1ST SHUNT RELEASE AC 230V, VOLTAGE OF 2ND SHUNT RELEASE AC 230V, VOLTAGE OF 3RD SHUNT RELEASE AC 230V, VOLTAGE OF OPERATING MECHANISM AC 230V, AUXILIARY SWITCH 12NO+12NC SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
43 | 3AH4305-6TE44-4EC2 | VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 2500A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 2 SHUNT RELEASES UNDERVOLTAGE RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, VOLTAGE OF 2ND SHUNT RELEASE DC 110V, VOLTAGE OF 3RD SHUNT RELEASE DC 110V, VOLTAGE OF OPERATING MECHANISM DC 110V, AUXILIARY SWITCH 12NO+12NC SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
44 | 3AH4306-6TK88-8KC2 | VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 40KA 2500A OPERATING.MECHAN. EU SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 2 SHUNT RELEASES UNDERVOLTAGE RELEASE VOLTAGE OF CLOSING SOLENOID AC 230V, VOLTAGE OF 1ST SHUNT RELEASE AC 230V, VOLTAGE OF 2ND SHUNT RELEASE AC 230V, VOLTAGE OF 3RD SHUNT RELEASE AC 230V, VOLTAGE OF OPERATING MECHANISM AC 230V, AUXILIARY SWITCH 12NO+12NC SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
45 | 3AH4306-6TE44-4EC2 | VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 40KA 2500A OPERATING.MECHAN. EU SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 2 SHUNT RELEASES UNDERVOLTAGE RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, VOLTAGE OF 2ND SHUNT RELEASE DC 110V, VOLTAGE OF 3RD SHUNT RELEASE DC 110V, VOLTAGE OF OPERATING MECHANISM DC 110V, AUXILIARY SWITCH 12NO+12NC SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
46 | 3AH4306-8TK88-8KC2 | VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 40KA 4000A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 2 SHUNT RELEASES UNDERVOLTAGE RELEASE VOLTAGE OF CLOSING SOLENOID AC 230V, VOLTAGE OF 1ST SHUNT RELEASE AC 230V, VOLTAGE OF 2ND SHUNT RELEASE AC 230V, VOLTAGE OF 3RD SHUNT RELEASE AC 230V, VOLTAGE OF OPERATING MECHANISM AC 230V, AUXILIARY SWITCH 12NO+12NC SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
47 | 3AH4306-8TE44-4EC2 | VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 40KA 4000A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 2 SHUNT RELEASES UNDERVOLTAGE RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, VOLTAGE OF 2ND SHUNT RELEASE DC 110V, VOLTAGE OF 3RD SHUNT RELEASE DC 110V, VOLTAGE OF OPERATING MECHANISM DC 110V, AUXILIARY SWITCH 12NO+12NC SECONDARY CONNECTION 64POLE PLUG CONNECTOR RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
48 | 3AY1715-6L | SPARE INTERRUPTER ASSEMBLIES COMPLETE FOR 3AH3425-2/4 3AH3426-2/4 3AH4305-2/4/6 |
49 | 3AY1715-1M | SPARE INTERRUPTER ASSEMBLIES COMPLETE FOR 3AH3305-2/4/6 Z H35 3AH3306-6 3AH4306-6, 3AH4785-2/4/6, 3AH4785-2/4/6 Z E26, 3AH4785-2/6 Z D31, 3AH4785-6 Z D31+E27 |
50 | 3AY1715-5M | SPARE INTERRUPTER ASSEMBLIES COMPLETE FOR 3AH3305-7/8 3AH3306-7/8 3AH4305-7/8 3AH4306-7/8 FOR 3AH4 AS OF FABR-NR.: 4434 OLDER FABR-NR. ON REQUEST |
51 | 3AY1510-5E | SPARE PART FOR 3AE,3AF,3AG,3AH OPERATING SOLENOID DC 100 – 124V AC 100V – 125V 50/60 HZ |
52 | 3AY1510-5F | SPARE PART FOR 3AE,3AF,3AG,3AH OPERATING SOLENOID DC 200V – 250V AC 230V – 240V 50/60 HZ |
53 | 3AY1711-2E | SPARE PART FOR 3AE, 3AG, 3AH1, 3AH2, 3AH5 DRIVE MOTOR, 100V/110V/125V DC |
54 | 3AY1511-3F | MOTOR FOR 3AF, 3AH3/4 AC 230-250V, 220-250V DC WITH INTEGR. VARISTOR |
55 | 3AX1103-2E | ACCESSORY FOR 3AC,3AE,3AF,3AG,3AH UNDERVOLTAGE RELEASE DC 110V INCL. VARISTOR |
56 | 3AX1103-2J | ACCESSORY FOR 3AC,3AE,3AF,3AG,3AH UNDERVOLTAGE RELEASE AC 50HZ 230V INCL. VARISTOR AND RECTIFIER |
57 | 3AH5154-1ME40-5EM2 | VACUUM CIRCUIT-BREAKER 12KV POLE-CENTRE DISTANCE 210MM 25KA 800A WITH 1ST SHUNT RELEASE WITH VARISTOR CIRCUITRY WITH CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, . WITH OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL COMPLETE WIRED WITH MOTOR OPERATED STORED- ENERGY MECHANISM DC 110V WITH AUXILIARY SWITCH 12NO+12NC WITH 64-POLE PLUG WITH MECHANICAL INTERLOCKING MOTOR AND TRIPPING ON WIRED TO LOWER PLUG PART, AUXILIARY SWITCH INTERNAL ON WIRED TO LOWER PLUG PART RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
58 | 3AH5154-2ME40-5EM2 | VACUUM CIRCUIT-BREAKER 12KV POLE-CENTRE DISTANCE 210MM 25KA 1250A WITH 1ST SHUNT RELEASE WITH VARISTOR CIRCUITRY WITH CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, . WITH OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL COMPLETE WIRED WITH MOTOR OPERATED STORED- ENERGY MECHANISM DC 110V WITH AUXILIARY SWITCH 12NO+12NC WITH 64-POLE PLUG WITH MECHANICAL INTERLOCKING MOTOR AND TRIPPING ON WIRED TO LOWER PLUG PART, AUXILIARY SWITCH INTERNAL ON WIRED TO LOWER PLUG PART RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
59 | 3AH5135-2ME40-5EM2 | VACUUM CIRCUIT-BREAKER 12KV POLE-CENTRE DISTANCE 210MM 31.5KA 1250A WITH 1ST SHUNT RELEASE WITH VARISTOR CIRCUITRY DC >= 60V WITH CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, . WITH OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL COMPLETE WIRED WITH MOTOR OPERATED STORED- ENERGY MECHANISM DC 110V WITH AUXILIARY SWITCH 12NO+12NC WITH 64-POLE PLUG WITH MECHANICAL INTERLOCKING MOTOR AND TRIPPING ON WIRED TO LOWER PLUG PART, AUXILIARY SWITCH INTERNAL ON WIRED TO LOWER PLUG PART RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
60 | 3AH5214-1ME40-5EM2 | VACUUM CIRCUIT-BREAKER 17.5KV POLE-CENTRE DISTANCE 210MM 25KA 800A WITH 1ST SHUNT RELEASE WITH VARISTOR CIRCUITRY DC >= 60V WITH CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, . WITH OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL COMPLETE WIRED WITH MOTOR OPERATED STORED- ENERGY MECHANISM DC 110V WITH AUXILIARY SWITCH 12NO+12NC WITH 64-POLE PLUG WITH MECHANICAL INTERLOCKING MOTOR AND TRIPPING ON WIRED TO LOWER PLUG PART, AUXILIARY SWITCH INTERNAL ON WIRED TO LOWER PLUG PART RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
61 | 3AH5312-2ME40-5EM2 | VACUUM CIRCUIT-BREAKER 36KV POLE-CENTRE DISTANCE 350MM 16KA 1250A WITH 1ST SHUNT RELEASE WITH VARISTOR CIRCUITRY DC >= 60V WITH CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, WITH OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL COMPLETE WIRED WITH MOTOR OPERATED STORED- ENERGY MECHANISM DC 110V WITH AUXILIARY SWITCH 12NO+12NC WITH 64-POLE PLUG WITH MECHANICAL INTERLOCKING MOTOR AND TRIPPING ON WIRED TO LOWER PLUG PART, AUXILIARY SWITCH INTERNAL ON WIRED TO LOWER PLUG PART RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
62 | 3AH5314-2ME40-5EM2 | VACUUM CIRCUIT-BREAKER 36KV POLE-CENTRE DISTANCE 350MM 25KA 1250A WITH 1ST SHUNT RELEASE WITH VARISTOR CIRCUITRY DC >= 60V WITH CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, WITH OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL COMPLETE WIRED WITH MOTOR OPERATED STORED- ENERGY MECHANISM DC 110V WITH AUXILIARY SWITCH 12NO+12NC WITH 64-POLE PLUG WITH MECHANICAL INTERLOCKING MOTOR AND TRIPPING ON WIRED TO LOWER PLUG PART, AUXILIARY SWITCH INTERNAL ON WIRED TO LOWER PLUG PART RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
63 | 3AH5314-4ME40-5EM2 | VACUUM CIRCUIT-BREAKER 36KV POLE-CENTRE DISTANCE 350MM 25KA 2000A WITH 1ST SHUNT RELEASE WITH VARISTOR CIRCUITRY DC >= 60V WITH CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, WITH OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL COMPLETE WIRED WITH MOTOR OPERATED STORED- ENERGY MECHANISM DC 110V WITH AUXILIARY SWITCH 12NO+12NC WITH 64-POLE PLUG WITH MECHANICAL INTERLOCKING MOTOR AND TRIPPING ON WIRED TO LOWER PLUG PART, AUXILIARY SWITCH INTERNAL ON WIRED TO LOWER PLUG PART RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
64 | 3AH3305-2ME40-0ED2 | VACUUM CIRCUIT-BREAKER 36KV POLE-CENTRE DISTANCE 350MM 31.5KA 1250A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 1 SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, . . VOLTAGE OF OPERATING MECHANISM DC 110V, AUXILIARY SWITCH 12NO+12NC SECONDARY CONNECTION 64POLE PLUG CONNECTOR MECHANICAL INTERLOCKING RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
65 | 3AH3305-4ME40-0ED2 | VACUUM CIRCUIT-BREAKER 36KV POLE-CENTRE DISTANCE 350MM 31.5KA 2000A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 1 SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, . . VOLTAGE OF OPERATING MECHANISM DC 110V, AUXILIARY SWITCH 12NO+12NC SECONDARY CONNECTION 64POLE PLUG CONNECTOR MECHANICAL INTERLOCKING RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
66 | 3AH3305-6ME40-0ED2 | VACUUM CIRCUIT-BREAKER 36KV POLE-CENTRE DISTANCE 350MM 31.5KA 2500A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 1 SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, . . VOLTAGE OF OPERATING MECHANISM DC 110V, AUXILIARY SWITCH 12NO+12NC SECONDARY CONNECTION 64POLE PLUG CONNECTOR MECHANICAL INTERLOCKING RATING PLATE AND INSTRUCTIONS IN ENGLISH, FREQUENCY OF SECONDARY VOLTAGE 50HZ |
67 | 3TM3231-1FA21-2AC0 | Vacuum Contactor 3TM three-pole rated voltage (Ur) 7.2kV (BIL 60kV / PFWV 20kV) rated normal current (Ir) 450A rated short-circuit breaking current (Isc), 1s (unfused) 5kA controller standard version operating voltage for magnet coil DC 110V without lachting delatching system not retrofittable pole-center distance 120mm additional closing time 50ms additional closing time 65ms release voltage without delatching system auxiliary cont./terminal strip 4NO+4NC without accessories |
68 | 3TM3431-1FA21-2AC0 | Vacuum Contactor 3TM three-pole rated voltage (Ur) 12kV (BIL 75kV / PFWV 28kV) rated normal current (Ir) 450A rated short-circuit breaking current (Isc), 1s (unfused) 5kA controller standard version operating voltage for magnet coil DC 110V without lachting delatching system not retrofittable pole-center distance 120mm additional closing time 50ms additional closing time 65ms release voltage without delatching system auxiliary cont./terminal strip 4NO+4NC without accessories |
69 | 3TL8100-1BA05 | VACUUM CONTACTOR 400A 7.2KV WITH SHORT OPERATING SHAFT WITH AUXILIARY SWITCH 4NO+4NC WITHOUT WIRING WITHOUT ADITIONAL MODULES OPERAT. VOLTAGE OF MAGNET COIL AC/DC 110V – 250V WITHOUT MECHANICAL CLOSING WITHOUT MECHANICAL CLOSING LATCHING, 325 +/- 75 MS DOCUMENTATION: OPERATING INSTRUCTIONS GERMAN / ENGLISH ROUTINE TEST REPORT ENGLISH |
70 | 3TL8100-5BA00 | VACUUM CONTACTOR 400A 7.2KV WITH SHORT OPERATING SHAFT WITH AUXILIARY SWITCH 4NO+4NC AUXILIARY CONTACTS WIREND TO TERMINAL STRIP WITHOUT LATCHING MECHANISM OPERAT. VOLTAGE OF MAGNET COIL AC/DC 110V – 250V WITHOUT MECHANICAL CLOSING WITHOUT MECHANICAL CLOSING LATCHING, 325 +/- 75 MS DOCUMENTATION: OPERATING INSTRUCTIONS GERMAN / ENGLISH |
71 | 3TL6123-0BF4 | VACUUM CONTACTOR 450A 7.2KV CENTRAL TERMINAL STRIP 6NO+5NC WITHOUT ADDITIONAL MODULES OPERATING VOLTAGE DC 110V |
72 | 3TL6525-0BF4 | VACUUM CONTACTOR 400A 12KV CENTRAL TERMINAL STRIP 6NO+5NC WITHOUT ADDITIONAL MODULES OPERATING VOLTAGE DC 110V |